<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-10 23-20-05
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.10 MHz 4/5, 35 dBuV CauseCom
Pilot RDS Phase Difference
8.5 kHz 4.6 kHz 79 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
20 kHz 21 kHz 958 0,5219
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
1,4 dBr 2,47 dBr 3,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"CauseCom" FE46 9 (Varied) 0 0 1 1 --:--
RT
" "
AF EON
-
FM Scope Station: 93.10 MHz, signal: 4/5 (35 dBuV) Max at: 21 kHz MIN: 20 kHz % above 75 kHz: 0,5219 Acquired: 2025/02/10 23:19:01 Total samples: 958 Equivalent time: 0:00:47 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 20 40
FM Scope MAX: 3,4 dBr MIN: 1,4 dBr AVE: 2,47 dBr % above 10,0 dBr: 0,0 Last value: 3,3 dBr (2025/02/10 23:19:01) Station: 93.10 MHz, signal: 4/5 (35 dBuV) 23:12 23:13 23:14 23:15 23:16 23:17 23:18 23:19 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality